Concept of Power Line Communication solution for Mesh DC Micro grid based on CAN protocol

  • Authors

    • Tran Thanh Kha
    • Yahoui Hamed
    • Genon Catalot Denis
    • Siauve Nicolas
    • Fourty Nicolas
    2018-03-11
    https://doi.org/10.14419/ijet.v7i2.6.10562
  • PLC, protocol, CAN, safety, Mesh DC microgrid, smart grid.
  • Abstract

    Recently, technologies related to smart grids have attracted more attention due to increasing the demand for renewable energy. One of the most important foundations of smart grids is commonly communications between energies services demands and responses. Almost all the operations on the grids are based on the communications, such as supervision, protection, and isolation. These operations request different requirements for data transmission. The communication technology needs to have high reliability, low latency, and a minimum throughput to guarantee interaction between elements. To limit wires, power line communication (PLC) is a natural choice to deliver bi-directional data transmission between network components to enable smart controller and management of the grid. This paper proposes a PLC solution as a data transmission method for the mesh type DC microgrid. This solution is designed to take advantage of a robust protocol of automotive network - Control Area Network (CAN). The presented architecture is thus intended to propose a PLC system compatible with CAN-bus to provide a safety protocol for DC microgrid with cost effective approach.

  • References

    1. lang=EN-AU>ADDIN
    2. Mendeley Bibliography CSL_BIBLIOGRAPHY [1] C. Cano, A. Pittolo, D. Malone, L. Lampe, A. M. Tonello, and A. G. Dabak, “State of the Art in Power Line Communications: From the Applications to the Medium,†IEEE J. Sel. Areas Commun., vol. 34, no. 7, pp. 1935–1952, Jul. 2016.

      [2] Y. Kabalci, “A survey on smart metering and smart grid communication,†Renew. Sustain. Energy Rev., vol. 57, pp. 302–318, 2016.

      [3] A. Mannan, D. K. Saxena, and M. Banday, “A Study on Power Line Communication,†IEEE Trans. Consum. Electron., vol. 4, no. 7, pp. 7–10, 2014.

      [4] B. Baraboi and Ariane Controls Inc, “Narrowband Powerline Communication - Applications and Challenges — Part I,†EDN Network, 2013. .

      [5] A. M. Tonello and A. Pittolo, “Considerations on Narrowband and Broadband Power Line Communication for Smart Grids,†pp. 13–18, 2015.

      [6] F. Benzi, T. Facchinetti, and D. Caprini, “Powerline communication protocols Review, evaluation and tests for automotive applications Francesco,†Pavia, 2008.

      [7] J. Jousse, N. Ginot, C. Batard, and E. Lemaire, “Power Line Communication Management of Battery Energy Storage in a Small-Scale Autonomous Photovoltaic System,†IEEE Trans. Smart Grid, vol. 8, no. 5, pp. 2129–2137.

      [8] B. C. Watterson, “Configure Controller Area Network ( CAN ) Bit Timing to Optimize Performance,†no. September, pp. 1–3, 2014.

      [9] S. Corrigan and I. Interface, “Introduction to the Controller Area Network ( CAN ),†Texas Instruments, no. August 2002, pp. 1–17, 2016.

      [10] CAN in Automation (CiA) e. V., “CANopen application layer and communication profile,†2011.

      [11] C. Device and M. Version, “CANopen Device Monitor User Manual,†2013.

      [12] Ampere Laboratory and LCIS Laboratory, “C 3 µ - Appel à projets générique 2015 - défi 2 Components , Control and Communication for Microgrids DC,†2015.

    3. mso-fareast-font-family:Batang;mso-ansi-language:EN-US;mso-fareast-language:
    4. KO;mso-bidi-language:AR-SA'>
  • Downloads

  • How to Cite

    Thanh Kha, T., Hamed, Y., Catalot Denis, G., Nicolas, S., & Nicolas, F. (2018). Concept of Power Line Communication solution for Mesh DC Micro grid based on CAN protocol. International Journal of Engineering & Technology, 7(2.6), 171-175. https://doi.org/10.14419/ijet.v7i2.6.10562

    Received date: 2018-03-24

    Accepted date: 2018-03-24

    Published date: 2018-03-11