Automatic generation control of a two area power system implementing IDDF controller under restructured environment
-
2018-04-03 https://doi.org/10.14419/ijet.v7i2.12.11350 -
AGC, Deregulated, IDDF, Load Frequency Control, LSA, Multi- Source, PID, Restructured Environment. -
Abstract
This paper presents the Automatic generation control of an interlinked power system in a restructured environment. The model consists of a hydro plant, a thermal plant and a diesel plant incorporated in both areas. The Area Control Error (ACE) is minimized with the help of a new controller called the Integral Double Derivative controller (IDDF) employed as a secondary controller in the proposed model. The controller parameters are optimized by a novel optimization scheme called the Lightning Search Algorithm. The proposed model is simulated under two market scenarios. The robustness of the system is also examined under step load perturbations, random loading conditions and parameter variation. The settling time of the IDDF controller is put to comparison with the PID controller and the supremacy is established.
Â
-
References
[1] Elgerd, Olle Ingemar. "Electric energy systems theory: an introduction." (1982).
[2] Kundur, Prabha, Neal J. Balu, and Mark G. Lauby. Power system stability and control. Vol. 7. New York: McGraw-hill, 1994.
[3] Li, Na, Changhong Zhao, and Lijun Chen. "Connecting automatic generation control and economic dispatch from an optimization view." IEEE Transactions on Control of Network Systems 3.3 (2016): 254-264.
[4] Rahman, Asadur, Lalit Chandra Saikia, and Nidul Sinha. "Maiden application of hybrid pattern search-biogeography based optimisation technique in automatic generation control of a multi-area system incorporating interline power flow controller." IET Generation, Transmission & Distribution 10.7 (2016): 1654-1662.
[5] Mohanty, Pradeep Kumar, et al. "Design and analysis of fuzzy PID controller with derivative filter for AGC in multi-area interconnected power system." IET Generation, Transmission & Distribution 10.15 (2016): 3764-3776.
[6] Panda, Sidhartha, N. P. Patidar, and Mohan Kolhe. "Cascaded PD-PI controller for active power frequency control of two-area multi-units power system." Power and Renewable Energy (ICPRE), IEEE International Conference on Power and. IEEE, 2016.
[7] Rahman, Asadur, Lalit Chandra Saikia, and Nidul Sinha. "Automatic generation control of an unequal four-area thermal system using biogeography-based optimised 3DOF-PID controller." IET Generation, Transmission & Distribution 10.16 (2016): 4118-4129.
[8] Pathak, Nikhil, Terlochan Singh Bhatti, and Ashu Verma. "Accurate Modelling of Discrete AGC Controllers for interconnected Power Systems." IET Generation, Transmission & Distribution (2017).
[9] Dahiya, Preeti, Veena Sharma, and Ram Naresh. "Automatic generation control using disrupted oppositional based gravitational search algorithm optimised sliding mode controller under deregulated environment." IET Generation, Transmission & Distribution 10.16 (2016): 3995-4005.
[10] Sharma, Gulshan, Khaleequr Rehman Niazi, and Ramesh C. Bansal. "Adaptive fuzzy critic based control design for AGC of power system connected via AC/DC tie-lines." IET Generation, Transmission & Distribution 11.2 (2017): 560-569.
[11] Yang, Chen-Wei, Victor Dubinin, and Valeriy Vyatkin. "Ontology Driven Approach to Generate Distributed Automation Control From Substation Automation Design." IEEE Transactions on Industrial Informatics 13.2 (2017): 668-679
[12] Pathak, Nikhil, T. S. Bhatti, and Ashu Verma. "Discrete Data AGC of Hydro-Thermal Systems under Varying Turbine Time Constants along with the Power System loading Conditions." IEEE Transactions on Industry Applications (2017).
[13] Bijami, Ehsan, and Malihe Farsangi. "Networked Distributed Automatic Generation Control of Power System with Dynamic Participation of Wind Turbines through Uncertain Delayed Communication Network." IET Renewable Power Generation (2017).
[14] Chakraborty, Tapabrata, David Watson, and Marianne Rodgers. "Automatic Generation Control Using an Energy Storage System in a Wind Park." IEEE Transactions on Power Systems 33.1 (2018): 198-205.
[15] Kumar, Nagendra, Barjeev Tyagi, and Vishal Kumar. "Application of fractional order PID controller for AGC under deregulated environment." International Journal of Automation and Computing 15.1 (2018): 84-93.
[16] Shareef, Hussain, Ahmad Asrul Ibrahim, and Ammar Hussein Mutlag. "Lightning search algorithm." Applied Soft Computing36 (2015): 315-333.
[17] Mishra, Dillip Kumar, Et Al. "Automatic Generation Control in Three Area Interconnected Thermal Power Units Using IDDF.
-
Downloads
-
How to Cite
Sinha, S., Kumar Mallick, R., Mohapatra, M., & Kumar Giri, R. (2018). Automatic generation control of a two area power system implementing IDDF controller under restructured environment. International Journal of Engineering & Technology, 7(2.12), 352-358. https://doi.org/10.14419/ijet.v7i2.12.11350Received date: 2018-04-10
Accepted date: 2018-04-10
Published date: 2018-04-03