An Atrial Fibrillation with Normal Limits using Signal Processing- A Review
-
2018-04-25 https://doi.org/10.14419/ijet.v7i2.24.12133 -
Abnormal P-waves, stroke, averaging methods, P-Ta segments, defibrillations circuits. -
Abstract
Atrial fibrillation is an irregular heartbeat (arrhythmia) that can lead to the stroke, blood clots, heart failure and other heart related complications. This causes the symptoms like rapid and irregular heartbeat, fluttering, shortness of breath etc. In India for every around 4000 people eight of them are suffering from Atrial Fibrillation. P-wave Morphology. Abnormality of P-wave (Atrial ECG components) seen during sinus rhythm are associated with Atrial fibrillation. P-wave duration is the best predictor of preoperative atrial fibrillation. but the small amplitudes of atrial ECG and its gradual increase from isometric line create difficulties in defining the onset of P wave in the Standard Lead Limb system (SLL).Studies shows that prolonged P-wave have duration in patients (PAF) In this Study, a Modified Lead Limb (MLL) which solves the practical difficulties in analyzing the P-ta interval for both in healthy subjects and Atrial Fibrillation patients. P-Ta wave interval and P-wave duration can be estimated with following proposed steps which is applicable for both filtered and unfiltered atrial ECG components which follows as the clinical database trials. For the same the p-wave fibrillated signals that escalates the diagnosis follows by providing minimal energy to recurrent into a normal sinus rhythm.
Â
Â
-
References
[1] Einthoven W. “The different forms of the human electrocardiogram and their signification.†Lancet 1912; 1: 853-61
[2] Atrial fibrillation in a tertiary care institute A prospective study2012 Sep; 64(5): 476–478.
[3] K. Konings, C. Kirchhof, J. Smeets, H. Wellens, et al., "High-density mapping of electrically induced atrial fibrillation in humans, Circulation, vol. 89, pp. 1665-80, 1994.
[4] ECG Acquisition, Storage, Transmission, and Representation Gari D. Clifford and Matt B. Oefinger.
[5] G. B. Moody, R. G. Mark, and A. L. Goldberger, “PhysioNet: A w web based resource for the study of physiological signals,†IEEE Engineering in Medicine and Biology Mag., vol. 20, no. 3, pp. 70– 75, 2001.
[6] Abboud, S., and O. Barnea, “Errors Due to Sampling Frequency of Electrocardiogram in Spectral Analysis of Heart Rate Signals with Low Variability,†Computers in Cardiology, Vol. 22, September 1995, pp. 461–463.
[7] Enhancement of ECG Signal by using Digital FIR Filter B. Jagadiswara Rao1, A. Usharani2., International Journal of Science and Research (IJSR)., India.
[8] Sivaraman J, Uma G, Venkatesan S, Umapathy M, Dhandapani VE. “A novel approach to determine atrial repolarization in electrocardiograms.†J Electrocardiol 2013; 46: e1
[9] Oppenheim, A. V., and R.W. Schafer, Discrete-Time Signal Processing, Englewood Cliffs, NJ: Prentice-Hall, 1999.
[10] Clifford, G. D., and P. E. McSharry, “Method to Filter ECGs and Evaluate Clinical Parameter Distortion Using Realistic ECG Model Parameter Fitting,†Computers in Cardiology, Vol. 32, 2005.
[11] C. Li, C. Zheng, and C. Tai, “Detection of ECG characteristic points using wavelet transforms,†IEEE Trans. Biomed. Eng., vol. 42, no. 1, Jan.1995.
[12] Sivaraman J, Uma G, Venkatesan S, Umapathy M, Keshav Kumar N. “A study on atrial Ta wave morphology in healthy subjects: Anapproach using P wave signal-averaging method.†J Med Imaging Health Inf 2014; 4: 675-80
[13] Joseph Ackora-Prah, Anthony Y. Aidoo “An Artificial ECG Signal Generate Function in MATLABâ€, Applied Mathematical Sciences, Vol.7, 2013, no. 54, 2675 - 2686 HIKARI Ltd
[14] Sivaraman J, Uma G, Venkatesan S, Umapathy M,Dhandapani VE. “Normal limits of ECG measurements related to atrial activity using a modified limb lead system.†Anatol J Cardiol 2014 Feb26. Epub ahead of print.
[15] Fujiki, H. Nagasawa, M. Sakabe, K. Sakurai, et al., "Spectral characteristics of human atrial fibrillation waves of the right atrial free wall with respect to the duration of atrial fibrillation and effect of class I antiarrhythmic drugs," Jpn Circ J, vol. 65, pp. 1047-51, 2001.
[16] S.V.Manikanthan and T.Padmapriya “Recent Trends In M2m Communications In 4g Networks And Evolution Towards 5gâ€, International Journal of Pure and Applied Mathematics, ISSN NO:1314-3395, Vol-115, Issue -8, Sep 2017.
[17] T.Padmapriya, S.V.Manikanthan, “An enhanced distributed evolved node-b architecture in 5G tele-communications network†, International Journal of Engineering & Technology, DOI: 10.14419/ijet.v7i2.8.10419, ISSN NO:2227-524X, Vol-7, No.2.9(2018)
-
Downloads
-
How to Cite
Sathish, S., & Mohanasundaram, K. (2018). An Atrial Fibrillation with Normal Limits using Signal Processing- A Review. International Journal of Engineering & Technology, 7(2.24), 453-456. https://doi.org/10.14419/ijet.v7i2.24.12133Received date: 2018-04-25
Accepted date: 2018-04-25
Published date: 2018-04-25