Automatic Synchronverter: Inverter Lacking a Devoted Synchronization Unit

  • Authors

    • S Manoj
    • S Pradeep Kumar
    • N Ashok Babu
    2018-05-03
    https://doi.org/10.14419/ijet.v7i2.25.12359
  • Distributed Generator, Point of Common Coupling, Pulse Width Modulation, Renewable Energy Source and Synchronous Generator.
  • Abstract

    The design of self-synchronized synchronverter is made by removing the keen synchronization unit. Synchronization with the grid takes place before connection and it will track the grid frequency after connection. Like the original synchronverter it functions in various modes to deliver the grid frequency as the reference frequency. The functions of frequency regulation, voltage regulation, real and reactive power control are maintained. Moreover, it can share the real power and reactive power accurately. Distributed energy sources delivers the major contribution to the power system operation. Generally the renewable sources are non-linear and uncontainable. Majority of renewable energy sources were associated to power systems through dc/ac converters. For this kind of application synchronizing the inverter with the grid is necessary before and after the connections to be made. It is one of the biggest challenges. So synchronverter is designed to deliver a scheme for power systems to regulate the renewable energy connected to the grid and enables smart grid integration.

     

  • References

    1. [1] Xioming Yuan, Merk W, Stemmler H, Allmeling J “Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions†IEEE Trans. Ind. Appl. Vol. 38, pp523 - 532, Mar/Apr 2002.

      [2] Zhong Q. C., and Weiss G.(2009) ‘Static synchronous generators for distributed generation and renewable energy’, Power Syst. Conf. Exhib. IEEE PES., pp. 1–6.

      [3] Zhong Q. C., and Weiss G.(2011) ‘Synchronverter: Inverters that the Mimic synchronous generators’, IEEE Trans. Ind. Electron., vol. 58, No. 4, pp. 1259–1267.

      [4] Svensson J.(2001) ‘Synchronization methods for grid-connected Voltage source converter’, IEE Proc. Generat., Transmiss. Distrib.vol. 148, no. 3, pp. 229–235.

      [5] Raouia Aouini Bogdan Marinescu Khadija Ben Kilani Mohammed Elleuch "Synchronverter-Based Emulation and Control of HVDC Transmission" IEEE Trans. Power Systems vol. 31 no. 1 pp. 278-286 Jan. 2016.

      [6] Shanmugasundaram N Vajubunnisa Begum R Ganesh N “Measurement and detection of voltage dips and swells in power circuits†International Journal of Engineering & Technology, 7 (2.8), 239-242, 2018.

      [7] Shanmugasundaram N Vajubunnisa Begum R “Modeling and Simulation Analysis of Power Cables for a Matrix Converter Fed Induction Motor Drive (MCIMD)†Jour of Adv Research in Dynamical & Control Systems, 11-Special Issue, November 2017.

      [8] Shanmugasundaram N Thangavel S “Modeling and Simulation Analysis of Power Cable a Three Level Inverter Fed Induction Motor Drive†Jour of Comput. Theor. Nanosci. Vol. 14, 972–978, 2017.

      [9] Saravanan K K Elankurisil S A “Analysis an investigation on photo voltaic system Stability for Grid connected Load†Journal of Electrical Engineering, Vol. 17,2017.

      [10] Ciobotaru M., Teodorescu R., and Blaabjerg F.(2006) ‘A new single-phase PLL structure based on second order generalized integrator’, in Proc. 37th IEEE Power Electron. Spec. Conf., pp. 1–6.

      [11] Rodriguez P., Pou J., Bergas J., Candela J., Burgos R., and Boroyevich D.(2007) ‘Decoupled double synchronous reference frame PLL for power converters control’, IEEE Trans. Power Electron., vol. 22, no. 2, pp. 584–592.

      [12] Singh B., Saha R., Chandra A., and Al-Haddad K.(2009) ‘Static synchronous compensators (STATCOM): A review’, IET Power Electron., vol. 2, no. 4, pp. 297–324.

      [13] Singh B., Saha R., Zhang Q., D-Sun X., Zhong Y.R., Matsui M., and Ren B.Y.(2011) ‘Analysis and design of a digital phase-locked loop for single-phase grid-connected power conversion systems’, IEEE Trans. Ind. Electron., vol. 58, no. 8,pp. 3581–3592.

      [14] Thacker T., Boroyevich D., Burgos R., and Wang F.(2011) ‘PLL noise reduction via phase detector implementation for Single- phase systems’, IEEE Trans. Ind. Electron., vol. 58, no. 6, pp. 2482–2490.

      [15] Midtsund T, Suul J. A, Undeland T "Evaluation of current controller performance and stability for voltage source converters connected to a weak grid"Proc. 2nd IEEE Int. Symp. Power Electron. Distrib. Gener. Syst. pp. 382-388 Jun. 2010.

      [16] Harnefors L, Bongiorno M, Lundberg S. "Input-admittance calculation and shaping for controlled voltage-source converters"IEEE Trans. Ind. Electron. vol. 54 no. 6 pp. 3323-3334 Dec. 2007.

      [17] Zhang L., Harnefors L., and Nee H. P.(2010) ‘Power-Synchronization control of grid-connected voltage-source converters’, IEEE Trans. Power Syst., vol. 25, no. 2, pp. 809–820.

  • Downloads

  • How to Cite

    Manoj, S., Pradeep Kumar, S., & Ashok Babu, N. (2018). Automatic Synchronverter: Inverter Lacking a Devoted Synchronization Unit. International Journal of Engineering & Technology, 7(2.25), 20-24. https://doi.org/10.14419/ijet.v7i2.25.12359

    Received date: 2018-05-03

    Accepted date: 2018-05-03

    Published date: 2018-05-03