Development of an experimental single-link flexible manipulator system
-
2018-05-22 https://doi.org/10.14419/ijet.v7i2.29.13116 -
Flexible Manipulator, Single-link Manipulator, Laboratory design -
Abstract
Demand for the applications of flexible manipulator due to their benefits has received attention from the industries. However, the flexibility of flexible manipulator has resulted in structural vibration and needs to be studied accordingly. This paper presents the development of a laboratory facility constituting of single-link flexible manipulator system. A new experimental rig flexible manipulator system constrained to move horizontally was designed, developed and fabricated. The experimental equipment setup and method of capturing data are presented. Experimental works have been done to highlight the effect of forces on hub-angle and end-point vibration of the flexible manipulator. Impact test was carried out to identify the dominant mode of vibration of the flexible manipulator. Result from the impact test was compared with the experimental data recorded for model validation and verification. The experimental result demonstrated that the reasonable accuracy with only 1.31% of error was obtained for the dominant mode of vibration. The experimental rig developed incorporating the sensors and actuators deployed may direct future researchers towards significant applications of flexible manipulator in the industrial sector and to promote better productivity.
Â
-
References
[1] Abdul Razak, N. (2007). Modeling of Single-link Flexible Manipulator with Flexible Joint. Master Thesis, Universiti Teknologi Malaysia, Skudai.
[2] Ahmad, M. A. and Mohamed, Z. (2008). Vibration Suppression Techniques in Feedback Control Loop of a Flexible Robot Manipulator. Modern Applied Science. 2(2), 59 – 71.
[3] Alam, M. S. and Tokhi, M. O. (2008). Designing feedforward command shapers with Multi-objective Genetic Optimisation for vibration control of a Single-link Flexible Manipulator. Engineering Applications of Artificial Intelligence. 21(2), 229 – 246.
[4] Choi, S. B., Cho, S. S., Shin, H. C., and Kim, H. K. (1999). Quantitative feedback theory control of a single-link flexible manipulator featuring piezoelectric actuator and sensor. Smart Material and Structure. 8(1999), 338 – 349.
[5] Ho, M. T. and Tu, Y. W. (2006). Position control of a Single-link Flexible Manipulator using H-infinity based PID control. IEEE Proceedings- Control Theory and Applications. 153(5), 615 – 622.
[6] Maouche, A. R. and Attari, M. (2008). Adaptive Neural Control of a Rotating Flexible Manipulator. International Symposium on Power Electronics, Electrical Drives, Automation and Motion. 517 – 522.
[7] Mohamed, Z., Tokhi, M. O. & Azad, A. K. M. (1996). Finite Difference and Finite Element Simulation of a Flexible Manipulator. Research Report no. 617, Department of Automatic Control & System Engineering. University of Sheffield, UK.
[8] Phan, V. P., Goo, N. S. and Park, H. C. (2009). Vibration Suppression of a Flexible Robot Manipulator with a Lightweight Piezo-composite Actuator. International Journal of Control, Automation and Systems. 7(2), 243 – 251.
[9] Physik Instrumente (PI) GmbH & Co. (2012). P-876 DuraAct Patch Transducer. Karlsruhe, Germany.
[10] Rovner, D. M. and Franklin, G. F. (1988). Experiments in Load-adaptive Control of a Very Flexible One-link Manipulator. Automatica. 24(4), 541 – 548.
[11] Rudrusamy, B. (2005). Optimal Input Shaping for Vibration Control of a Flexible Manipulator using Genetic Algorithm. Master Thesis. Universiti Teknologi Malaysia, Skudai.
[12] Ryu, J. H., Kwon, D. S. and Park Y. (2000). A Robust Controller Design Method for a Flexible Manipulator with a Large Time Varying Payload and Parameter Uncertainties. Journal of Intelligent and Robotic Systems. 27, 345 – 361.
[13] Tokhi, M.O., and Azad, A.K.M. (1996). Design and Development of an experimental flexible manipulator system. Robotica. 15, 283 – 292.
[14] Tokhi, M. O., Mohamed, Z. and Shaheed, M. H. (2001). Dynamic Characterization of a Flexible Manipulator System, Robotica. 19, 571 – 580.
[15] Vakil, M. (2008). Dynamics and Control of Flexible Manipulators. Doctor of Philosophy Thesis, University of Saskatchewan, Saskatoon, Canada.
-
Downloads
-
How to Cite
Mohd Yatim, H., & Zaurah Mat Darus, I. (2018). Development of an experimental single-link flexible manipulator system. International Journal of Engineering & Technology, 7(2.29), 7-14. https://doi.org/10.14419/ijet.v7i2.29.13116Received date: 2018-05-21
Accepted date: 2018-05-21
Published date: 2018-05-22