Modeling and simulation of HVRT and LVRT enhancement capability for doubly fed induction generator based wind energy conversion system

  • Authors

    • Srinivasan P
    • Dhandapani Samiappan
    2018-06-08
    https://doi.org/10.14419/ijet.v7i2.33.14196
  • WECS, LVRT, HVRT, Grid Code and Power Converters.
  • Abstract

    Generation of power using wind turbine is more across the globe, but a problem related using wind method of power generation is volt-age variation across the grid. The performance of wind turbine goes below the specified level during grid voltage variation. It might be due to overvoltage or under voltage condition. Under voltage capability of WECS is called to be LVRT i.e. Low Voltage Ride Through and over voltage or high voltage capability of WECS is called High Voltage Ride Through (HVRT). Due to unfortunate grid voltage variation the converters connected to wind turbines are affected hence these devices needs to be prevented from lowering of voltage and increase in voltage. Therefore an algorithm is been developed to overcome LVRT and HVRT effects and to protect DFIG under this condition without distressing its routine. Simulation results and system modeling shows that effectiveness under various operating con-dition.

     

  • References

    1. [1] Vladislav Akhmatov, “Induction Generators for Wind Powerâ€,Multi-Science publishers, June 2007.

      [2] Muller, S., Deicke, M., De Doncker, R.W. 2002. “Doubly Fed Induction Generator Systems for Wind Turbinesâ€, IEEE Industry Applications Magazine, Vol. 8, Issue 3, May-June 2002, pp. 26- 33.

      [3] Morren, J., de Haan, and S.W.H. 2005. “Ridethrough of Wind Turbines with Doubly-Fed Induction Generator during A Voltage Dipâ€, IEEE Transactions on Energy Conversion, Vol. 20, Issue 2, June 2005, pp. 435-441.

      [4] Ledesma, P. and Usaola, J. 2005. “Doubly Fed Induction Generator Model for Transient Stability Analysisâ€, IEEE Transactions on Energy Conversion, Vol. 20, Issue 2, June 2005, pp.388-397.

      [5] Weihao Hu et al,“Low Voltage Ride-Through of Variable Speed Wind Turbines with Permanent Magnet Synchronous Generatorâ€, EVRE Conference, March 2009.

      [6] J.M. Carrasco“Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey†IEEE Transactions on Industrial Electronics, Vol 53, No.4, August 2006 pp 1002-1016.

      [7] EON GmbH Grid Code- High voltage and Extra High voltage, April 2006.

      [8] Keliang Zhou and Danwei Wang “Relationship between Space-Vector Modulation and Three-Phase Carrier-Based PWM: A Comprehensive Analysis†IEEE Transactions on Industrial Electronics, Vol 49, No.1, Feb 2002.

      [9] C. Wessels, F.W. Fuchs, “High Voltage Ride Through with FACTS for Wind Turbines with Doubly Fed Induction Generatorâ€,EPE 2009, pp P.1-P.10.

      [10] Matlab/SImulink user guide, 2009, Mathworks. www.mathworks.com