Feed Solution in the Pipeline aith the Compensators Mortar Pump of Various Design Solutions Pressure Pulsations Degree Determination

  • Authors

    • Bogdan Korobko
    • Viktor Virchenko
    • Mykola Shapoval
    2018-06-20
    https://doi.org/10.14419/ijet.v7i3.2.14402
  • mortar pump with a combined compensator of increased volume, the degree of pressure pulsations, solution mobility, reduced volume of compensator.
  • The article deals with the mortar pump with ball spring-loaded suction and delivery valves, a special insert in the suction chamber and compensators of various design solutions. Comparative analysis to determine the degree of pressure pulsation of the mortar pump with various compensators is presented. On the basis of theoretical and experimental studies, it has been proven that mortar pump with a combined compensator of increased volume has lower pulsation levels relative to the pulsations in the mortar pump compensator with combined pressure pulsations compensator. Rational parameters of the compensator of increased mortar’s volume are defined.

     

     

  • References

    1. [1] Kukoba A. T. Changing the volume of the dissolved mixture when pumping with the solvent pump / Kukoba A.T., Korobko B.O., Vasiliev A. V. // Mechanization of construction.-2000. - No. 3.

      [2] Onishchenko A. G. Method of calculation the return losses of a solution through a suction valve of a vertical differential mortar pump // Collection of scientific works (industrial engineering, construction) / Onishchenko A. G. , Kukoba A. T., Ustiantsev V. U.// Poltava State Technical Yuri Kondratyuk University. - Issue 3. - Poltava: Poltava State Technical University, 1998. - P. 3-6.

      [3] O. G. Onyshchenko, M. V. Shapoval, A. Vasiliev Single-piston mortar pump with combined pressure compensator // Mechanization of Construction. Moscow - 2001. - No. 4. - P. 4-6.

      [4] Chinayev I. A. Piston crank pumps. / Chinayev I. A. / - L.: Mechanical Engineering, Leningrad department- 1983. - 156 p.

      [5] Parfenov E. P. Determination of piston mortar pump performance/ Parfenov E. P. // Mechanical tools and finishing machines: Informational Scientific and Technical Collection - Issue 4 - Moscow: TsNIITEstroymash, 1972. - December 12-13.

      [6] Mortelpumpen und ihre Entwicklung // "Fordern und Heben". - 1969. - No. 15. (FRG)

      [7] EP 0200026, INT. Cl 4 F 04 B 43/12, 15/02. Pumpe Neumuller Walter, Sturmer Gerhard. - 10/12/1986. - Patentblatt 86/45.

      [8] Korobko B. (2016), Investigation of energy consumption in the course of plastering machine’s work, Eastern-European Journal of Enterprise Technologies, 4/8 (82), 4 – 11. DOI: 10.15587/1729-4061.2016.73336.

      [9] Vatin N, Gamayunova O 2014 Using plastering machines to improve the efficiency of finishing works AMM 635-637 pp. 2049-2053

      Chen, X. Experimental and modeling study of dynamic mechanical properties of cement paste, mortar and concrete [Text] / X. Chen, S. Wu, J. Zhou // Construction and Building Materials. – 2013. – Vol. 47. – P. 419–430. doi: 10.1016/j.conbuildmat.2013.05.063
  • Downloads

  • How to Cite

    Korobko, B., Virchenko, V., & Shapoval, M. (2018). Feed Solution in the Pipeline aith the Compensators Mortar Pump of Various Design Solutions Pressure Pulsations Degree Determination. International Journal of Engineering & Technology, 7(3.2), 195-202. https://doi.org/10.14419/ijet.v7i3.2.14402