An objective study of behavior of permanent magnet synchronous motor under abnormal conditions
-
2018-09-05 https://doi.org/10.14419/ijet.v7i4.15550 -
PMSM, Short Interruptions, Faults, Broken Rotor Bar. -
Abstract
Permanent magnet synchronous motors (PMSM) can be used directly in place of the induction motors (I.M) for several industrial applications since it is characterized by high efficiency, high power factor, and high power compared to I.M. However, this type of motor suffers from some abnormal conditions that result in minimizing power quality such as voltage sags, temporary disturbances, and faults within the network. In this paper, the behavior of PMSM has been studied under the above conditions in a Matlab/Simulink environment. It was noticed that such problems caused an increase in the amount of torque and current in this motor which impacted negatively on the motor speed and influenced the behavior of PMSM.
Â
-
References
[1] C.A. da Silva, J. Cardoso, and R. Carlson, “Analysis of a Three-Phase LSPMM by Numerical Method,†IEEE Trans. Magnetics, Vol. 45, No. 3, March 2009, pp.1792-1795. https://doi.org/10.1109/TMAG.2009.2012823.
[2] Ugale, R.T., Bhanuji, A. and Chaudhari, B.N., 2009, January. A novel line start permanent magnet synchronous motor using two-part rotor. In TENCON 2009-2009 IEEE Region 10 Conference (pp. 1-5). IEEE. https://doi.org/10.1109/TENCON.2009.5395857.
[3] Ashok ,K. R., Balaji, K, Sensor less control of PMSM fed from three phase four switch inverter based on back EMF observer and sliding mode controller with fast reaching law. International Journal of Engineering & Technology, vol. 7, no. 2, 2018, 725 - 731.https:// doi: 10.14419/ijet.v7i2.10847.
[4] Ugale, R.T., BalaKrishna, Y. and Chaudhari, B.N., 2008, April. Effects of short power interruptions and voltage sags on the performance of line start permanent magnet synchronous motor. In Power Electronics, Machines and Drives, 2008. PEMD 2008. 4th IET Conference on (pp. 184-188). IET.
[5] Miller, T.J.E., 1984. Synchronization of line-start permanent-magnet ac motors. IEEE Transactions on Power Apparatus and Systems, (7), pp.1822-1828. https://doi.org/10.1109/TPAS.1984.318630.
[6] Ugale, R.T. and Chaudhari, B.N., 2008, April. Effect of short power interruptions on performance of AC motors. In Industrial Technology, 2008. ICIT 2008. IEEE International Conference on (pp. 1-5). IEEE. https://doi.org/10.1109/ICIT.2008.4608323.
[7] Gomez, J.C., Morcos, M.M., Reineri, C. and Campetelli, G., 2001. Induction motor behavior under short interruptions and voltage sags. IEEE Power Engineering Review, 21(2), pp.11-15. https://doi.org/10.1109/39.896812.
[8] Douglas, H., Pillay, P. and Ziarani, A., 2003, June. Detection of broken rotor bars in induction motors using wavelet analysis. In IEEE International Electric Machines and Drives Conference, IEMDC'03. https://doi.org/10.1109/IEMDC.2003.1210345.
[9] An, G. and Li, H., 2017. Stator and Rotor Faults Diagnosis of Squirrel Cage Motor Based on Fundamental Component Extraction Method. International Journal of Rotating Machinery, 2017. https://doi.org/10.1155/2017/1576381.
[10] Karmakar, S., Chattopadhyay, S., Mitra, M. and Sengupta, S., 2016. Induction motor and faults. In Induction Motor Fault Diagnosis (pp. 7-28). Springer, Singapore. https://doi.org/10.1007/978-981-10-0624-1_2.
[11] ollen, HJ, Society, IP, Society, IP & Society, II 2000, Understanding power quality problems: voltage sags and interruptions, IEEE Press ; Wily-Interscience, New York : Hoboken, N.J.
[12] Mcgranaghan, M & Roettger, B 2002, 'Economic Evaluation of Power Quality', Power Engineering Review, IEEE, vol. 22, no. 2, pp. 8-12. https://doi.org/10.1109/MPER.2002.981339.
[13] Djokic, S & Milanovic, J 2006, 'Advanced voltage sag characterisation. Part 1: Phase shift', Iee Proceedings-Generation Transmission and Distribution, vol. 153, no. 4, pp. 423-430. https://doi.org/10.1049/ip-gtd:20050350.
-
Downloads
-
How to Cite
H. Al-Tameemi, Z., H. Enawi, H., M. Al-Anbary, K., H. Al-Mamoori, D., & M. Almukhtar, H. (2018). An objective study of behavior of permanent magnet synchronous motor under abnormal conditions. International Journal of Engineering & Technology, 7(4), 1977-1982. https://doi.org/10.14419/ijet.v7i4.15550Received date: 2018-07-13
Accepted date: 2018-08-20
Published date: 2018-09-05