Evaluation of Cathodic Protection Criteria for Embedded Steel Reinforcement in concrete structures
-
2018-07-20 https://doi.org/10.14419/ijet.v7i3.12.16099 -
Reinforced Concrete, Sacrificial Protection, Ribbon type Anode, Ion Conductive Polymer Backfill, Sacrificial Anode -
Abstract
This paper presents the results of performance of sacrificial protection in preventing the rebar corrosion in chloride contaminated and chloride free concrete. In this present study, the effectiveness of sacrificial protection of embedded steel rebars has been evaluated on chloride contaminated and chloride free concrete slabs using ribbon type Zinc anodes with ion conductive polymer backfill over a period of 250 days of exposure. The results showed that the ribbon type zinc sacrificial anodes with the navel electrochemical interface (Ion conductive polymer backfill) can confer effective corrosion protection of embedded steel in concrete on preventing corrosion initiation in chloride contaminated as well as chloride free concretes slabs. The cathodic protection criteria evaluated on concrete unit slab showed that 100-150mV is necessary in the atmospheric exposure and 160-200mV under alternate wetting & drying conditions.
Â
-
References
[1] Page C.L., Cathodic Protection of Steel in Concrete-Principles and applications. Proceeding of international conference on Repair of Concrete Structures theory and practice in a Marine environment, Solver (Norway), Vol.28-30, 1997, pp. 123-13.
[2] Pedeferri P, Cathodic protection of new concrete construction. In. Proceedings of the international Conference on Structural Improvement through Corrosion Protection of Reinforced Concrete, Institute of Corrosion, London 1992.
[3] Bertolini L, Bolzolini L, Pastore T and Pedeferri P, New experiences in Cathodic Prevention of reinforced Concrete Structures. In: C.L.Page et al Corrosion of Reinforced Concrete, Society of Chemical Industry, London 1996.
[4] Bertolini L, Bolzolini L, Pastore T and Pedeferri P, Three Year Test on Cathodic Prevention of reinforced Concrete Structures, International Conference on Corrosion, Corrosion 97, 1997, paper 244, NACE, Houston.
[5] Standard EN 126696-1, Cathodic Protection of Steel in Atmospherically Exposed Concrete, March 2000.
[6] Glass GK, Analysis of data on Reinforced Concrete Cathodic Protection System’, Material Performance, Vol.35, No. 3, 1996, pp.29-35.
[7] Eons D.G., Williams A.J and Scrully J.R, Long-term effect of Cathodic protection on pre-stressed concrete Structures-Hydrogen Embrittlement of Prestressing Steel’ Corrosion Journal, Vol.53, No. 11, 1997, pp.891-908.
[8] Hassanein A.M., Glass G.K and Buenfeld N.R., Effect of Intermittent Cathodic Protection on Chloride and Hydroxyl ion concentration Profiles in reinforced concrete’ British Corrosion Journal, Vol. 34, No.4,1999, pp254-261.
[9] Robert Brown P and John Tinnea S. Cathodic Protection design Problems for Reinforced concrete’, Materials Performance, Vol.30, No.8, 1991, pp 28-31.
[10] Sagues and Krane S.C., Determination of Polarisation Diagrams of Reinforcing Steel in Concrete’ Corrosion, Vol.48, 1992, No.8, pp.624-633.
[11] De Rincon OT, De Romero D.M et al., Corrosion Monitoring of Steel reinforcement bars in concrete environment, journal of Material Structures’, Vol. 30, 1997, pp. 556.
[12] Krane S.C, Sagues A.A, Presuel Moreno F.J, Computational and Experimental investigation of Cathodic Protection current distribution in reinforced concrete of Marine Piling, Corrosion 97, 1997, pp 231.
[13] Sagues A.A, Krane S.C and Presuel Moreno F.J and Silva Araya W.I, Advanced Computational Model for Sacrificial Cathodic Protection of submerged reinforced concrete Marine Footers. Repair and Rehabilitation of Reinforced Concrete Structures. The State of the Art, American Society of Civil Engineering, Reston, 1997, pp. 1-13.
[14] Glass G.K and Buenfeld N.R. (2002), ‘Influence of Chloride Binding on the Chloride Induced Corrosion Risk in Reinforced Concrete’, Corrosion Science, Vol. 42, 2002, No. 2, pp. 329-344.
[15] Chang J.J. A Study of the bond Degradation of Rebar due to Cathodic Protection Current, Journal of Cement and Concrete Research, Vol. 32, 2002, pp.657-663.
[16] Metwally et al, Factors affecting Cathodic Protection Interference, Journal of Engineering Analysis with Boundary Elements, vol. 31, No. 6, 2007, pp. 485-490.
[17] Effect of Intermittent Cathodic Protection on Chloride and Hydroxyl ion concentration Profiles in reinforced concrete’ British Corrosion Journal, Vol. 34, No.4, 2006, pp254-261.
[18] Andrade M et al and Welde B.E., Control of Cathodic Protection in Bridges without disconnecting protection current: Passivity verification Technique (PVT) Journal of Corrosion Engineering, Science and Technology.Vol.42, No. 3, 2007, pp. 215-223.
[19] Bertolini et al., Effects of Cathodic Prevention on the Chloride Threshold for Steel Corrosion In Concrete, Journal of Electrochemical Acta, Vol. 54, No. 5, 2009, pp. 1452-1458.
[20] Persa M.H.et al, Simulation of Cathodic protection Potential Distribution on Oil well casings, Journal of Petroleum Science and Engineering, Vol. 72, No. 4, 2007, pp 215-219.
[21] Ken pit house, A review of Cathodic Protection Systems Currently available to combat rebar corrosion caused by chloride ingress in concrete, Anti-corrosion Methods and Materials, 1997, Vol. 34, No. 8, pp. 12-13.
National Association for Corrosion Engineers (NACE) standard, Houston, Texas Cathodic Protection of Reinforcing steel in Atmospherically Exposed Concrete Structures, REPORT No. 290, 1990, pp. 268-278
-
Downloads
-
How to Cite
Dolli, H., Kavitha, A., & ., J. (2018). Evaluation of Cathodic Protection Criteria for Embedded Steel Reinforcement in concrete structures. International Journal of Engineering & Technology, 7(3.12), 333-336. https://doi.org/10.14419/ijet.v7i3.12.16099Received date: 2018-07-23
Accepted date: 2018-07-23
Published date: 2018-07-20