Study and Analysis of Performance of a Commercial Grid-Connected Rooftop Solar PV Plant

  • Authors

    • C Balaji
    • Shikhar Sahai
    • Subham Jha
    • S Sakthi
    • Baishali Mukherjee
    • A Dominic Savio
    • Abhishek Chakraborthi
    https://doi.org/10.14419/ijet.v7i3.23.19258
  • Solar Power Plant, HelioScope, Performance Ratio, Capacity Utilization Factor, Rooftop PV
  • Abstract

    This paper analyzes the performance of a rooftop solar PV plant installed in Chandigarh, India. The generation data of the grid-connected plant was collected via remote monitoring and was used to calculate the performance parameters like Performance Ratio and Capacity Utilization Factor using many other parameters as defined in international standards, like different yields, were also calculated. These parameters have then been compared with those obtained from simulations performed for the same plant. HelioScope was used to estimate the performance parameters mentioned using meteorological and solar radiation resource data. Various other parameters and losses related to the plant’s performance have been reported graphically and have been studied and analyzed. Hypothesis testing using P90 and P50 analysis has been carried out to report the statistical significance of PV generation estimated from commercial softwares.

     

  • References

    1. [1] Doolla S, Banerjee R. Diffusion of grid connected PV in India:

      [2] an analysis of variations incapacity factor. Proc. 35th IEEE pho

      [3] to voltaic specialists conference; 2010. [Berlin].

      [4] Ayompe LM, Duffy A, McCormack SJ, Conlon M. Measured

      1. performance of a 1.72 kW rooftop grid connected photovoltaic system in Ireland. Energy Convers and Manage2011;52: 816–25.

      [5] Chokmaviroj S, Wattanapong R, Suchart Y. Performance of a 500 kWp grid connected photovoltaic system at Mae Hong Son Province, Thailand. Renew Energy 2006;31: 19–28.

      [6] Drif M, Perez PJ, Aguilera J, Almonacid G, Gomez P, Casa J, et al. University project. A grid connected photovoltaic system of 200 kWp at Jaen University. Overview and performance analysis. Sol Energy Mater Sol Cells 2007;91:670–83.

      [7] IEA (International Energy Agency). Country reports on PV system performance, Report

      [8] IEA-PVPS T2-05:2004; 2005. Technical Report

      [9] George M, Banerjee R. Amethodology for analysis of impacts of grid integration of renewable energy. Energy Policy 2011;39:1265–76

      [10] IEA (International Energy Agency). Costs and performance trends in grid connected photovoltaics systems and case studies Report.

      [11] Report IEA PVPS T2-06; 2007 report.

      [12] IEC. (International Electro-technical Commission). Photovoltaic system performance monitoring — guidelines for measurement, data exchange and analysis, IEC 61724.1998.

      [13] Jahn U, Mayer D, Heidenreich M, Dahl R, Castello S, Clavadetscher L, et al. International Energy Agency PVPS Task 2: analysis of the operational performance of the IEA database

      [14] PV systems. Proc. 16th European photovoltaic energy conference and exhibition;2000. [Glasgow, United Kingdom].

      [15] JNNSM (Jawaharlal Nehru National Solar Mission). Mission Document.2008
      [14] Marion B, Adelstein J, Boyle K. Performance parameters for the grid connected PV systems.

      [16] Proc. 31st IEEE photovoltaic specialists conference and exhibition; 2005.[Florida].

      [17] Mau S, Jahn U. Performance analysis of grid connected PV systems.Proc.21stEuropean
      [17] Performance analysis of a 3 MWp grid connected solar photovoltaic power plant in India, K. Padmavathi, S. Arul Daniel

      [18] Performance analysis of 1MW grid connected photovoltaic power plant in Jaipur, India, Tahira Bano, KVS Rao

  • Downloads

  • How to Cite

    Balaji, C., Sahai, S., Jha, S., Sakthi, S., Mukherjee, B., Dominic Savio, A., & Chakraborthi, A. (2018). Study and Analysis of Performance of a Commercial Grid-Connected Rooftop Solar PV Plant. International Journal of Engineering & Technology, 7(3.23), 519-522. https://doi.org/10.14419/ijet.v7i3.23.19258

    Received date: 2018-09-08