Speckle Filtering Method in the Gonad Ultrasound Image for Mahseer’s Fish (Tor Tombroides)

  • Authors

    • Nurul Asmaa Abd Razak
    • Hizmawati Madzin
    • Fatimah Khalid
    • Mas Rina Mustaffa
    2018-12-09
    https://doi.org/10.14419/ijet.v7i4.31.23334
  • Aquaculture, Filtering, Mahseer, Speckle Filtering, Ultrasound
  • In fish breeding production, it is crucial to know the maturation of the eggs before spawning. In order to do that, possible use of ultrasound in identifying the eggs in the gonad is investigated. From the previous studies, ultrasound imaging can be affected by speckle noise. Moreover, with the similarity and subtle difference between the speckle noise and mahseer eggs, there is a need to identify the suitable speckle filtering methods in order to find out the eggs in the gonad ultrasound image. Five speckle filtering methods, which are Mean, Median, Wiener, Speckle Reducing Anisotropic Diffusion (SRAD) and Optimized Bayesian Nonlocal Mean (OBNLM) are tested and compared. From the result, it is proven that Median filter is the best speckle filtering method compared to other four filtering method in order to eliminate the speckle noise in the gonad ultrasound image.

     

     

  • References

    1. [1] Nguyen, T. T. T., Ingram, B., Sungan, S., Gooley, G., Sim, S. Y., Tinggi, D., & Silva, S. S. De. (2006). Mitochondrial DNA diversity of broodstock of two indigenous mahseer species, Tor tambroides and T. douronensis (Cyprinidae) cultured in Sarawak, Malaysia. Aquaculture, 253, 259–269.

      [2] Ingram, B., Sungan, S., Gooley, G., Sim, S. Y., Tinggi, D., & Silva, S. S. De. (2005). Induced spawning, larval development and rearing of two indigenous malaysian mahseer, Tor tambroides and T.douronensis. Aquaculture Research, 36, 1001–1014.

      [3] Macri, F., Rapisarda, G., Marino, G., Majo, M. De, & Aiudi, G. (2011). Use of Laparoscopy for the Evaluation of the Reproductive Status of Tench (Tinca tinca). Reproduction in Domestic Animals, 46, 130–133.

      [4] McBride, R. S., Wuenschel, M. J., Nitschke, P., Thornton, G., & King, J. R. (2013). Latitudinal and stock-specific variation in size- and age-at-maturity of female winter flounder, Pseudopleuronectes americanus, as determined with gonad histology. Journal of Sea Research, 75, 41–51.

      [5] Loher, T., & Stephens, S. M. (2011). Use of Veterinary Ultrasound to Identify Sex and Assess Female Maturity of Pacific Halibut in Nonspawning Condition. North American Journal of Fisheries Management, 31, 1034–1042.

      [6] Swenson, E. A., Rosenberger, A. E., & Howell, P. J. (2007). Validation of Endoscopy for Determination of Maturity in Small Salmonids and Sex of Mature Individuals. Transactions of the American Fisheries Society, 136, 994–998.

      [7] Du, H., Zhang, X., Leng, X., Zhang, S., Luo, J., Liu, Z., … Wei, Q. (2017). Gender and gonadal maturity stage identification of captive Chinese sturgeon, Acipenser sinensis, using ultrasound imagery and sex steroids. General and Comparative Endocrinology, 245, 36–43.

      [8] Colombier, S. B. du, Jacobs, L., Gessets, C., Elie, P., & Lambert, P. (2015). Ultrasonography as a non-invasive tool for sex determination and maturation monitoring in silver eels. Fisheries Research, 164, 50–58.

      [9] Petochi, T., Marco, P. Di, Donadelli, V., Longobardi, A., Corsalini, I., Bertotto, D., … Marino, G. (2011). Sex and reproductive stage identification of sturgeon hybrids (Acipenser naccarii x Acipenser baerii) using different tools: ultrasounds, histology and sex steroids. Journal of Applied Ichthyology, 27, 637–642.

      [10] Daly, J., Gunn, I., Kirby, N., Jones, R., & Galloway, D. (2007). Ultrasound Examination and Behaviour Scoring of Captive Broadnose Sevengill Sharks, Notorynchus cepedianus (Peron, 1807). Zoo Biology, 26, 383–395.

      [11] Chiotti, J. A., Boase, J. C., Hondorp, D. W., & Briggs, A. S. (2016). Assigning Sex and Reproductive Stage to Adult Lake Sturgeon using Ultrasonography and Common Morphological Measurements. North American Journal of Fisheries Management, 36, 21–29.

      [12] Bryan, J. L., Wildhaber, M. L., Papoulias, D. M., DeLonay, A. J., Tillitt, D. E., & Annis, M. L. (2007). Estimation of gonad volume, fecundity, and reproductive stage of shovelnose sturgeon using sonography and endoscopy with application to the endangered pallid sturgeon. Journal of Applied Ichthyology, 23, 411–419.

      [13] Martin-Robichaud, D. J., & Berlinsky, D. L. (2004). The effects of photothermal manipulations on reproductive development in female haddock Melanogrammus aeglefinus. Aquaculture Research, 35, 466–472.

      [14] Will, T. A., Reinert, T. R., & Jennings, C. A. (2002). Maturation and fecundity of a stock-enhanced population of striped bass in the Savannah River Estuary,USA. Journal of Fish Biology, 60, 532–544.

      [15] Jennings, C. A., Will, T. A., & Reinert, T. R. (2005). Efficacy of a high- and low- frequency ultrasonic probe for measuring ovary volume and estimating fecundity of striped bass Morone saxatilis in the Savannah River Estuary. Journal of Fisheries Research, 76, 445–453.

      [16] Hliwa, P., Bah, M., Kuz´min´ski, H., & Dobosz, S. (2014). Ultrasound evaluation of the gonadal structure in sex-reversed rainbow trout females. Aquaculture International, 22, 89–96.

      [17] Bryan, J. L., Wildhaber, M. L., & Noltie, D. B. (2005). Examining neosho madtom reproductive biology using ultrasound and artificial photothermal cycles. Journal of Aquaculture, 67, 221–230.

      [18] Achionye-Nzeh, C. G., & Jimoh, K. O. (2010). Ultrasound evaluation of the gonads in catfish clarias gariepinus (Teugels): An Initial Experience in Africa. Journal of Fish and Marine Sciences, 2(4).

      [19] Protopapadakis, L., Penttila, K., & Dowd, W. W. (2015). Management and Ecological Note: Testing a non-lethal method for determining the sex of California halibut, Paralichthys californicus, in non-spawning condition. Fisheries Management and Ecology, 22(5), 432–435.

      [20] Loher, T., & Stephens, S. M. (2011). Use of Veterinary Ultrasound to Identify Sex and Assess Female Maturity of Pacific Halibut in Nonspawning Condition. North American Journal of Fisheries Management, 31, 1034–1042.

      [21] Kohn, Y. Y., Lokman, P. M., Kilimnik, A., & Symonds, J. E. (2013). Sex identification in captive hapuku (Polyprion oxygeneios) using ultrasound imagery and plasma levels of vitellogenin and sex steroids. Aquaculture, 384–387, 87–93.

      [22] Whittamore, J. M., Bloomer, C., Hanna, G. M., & McCarthy, I. D. (2010). Evaluating ultrasonography as a non-lethal method for the assessment of maturity in oviparous elasmobranchs. Marine Biology, 157, 2613–2624.

      [23] Frost, D. A., McAuley, W. C., Kluver, B., Wastel, M., Maynard, D., & Flagg, T. A. (2014). Methods and Accuracy of Sexing Sockeye Salmon Using Ultrasound for Captive Broodstock Management. North American Journal of Aquaculture, 76, 153–158.

      [24] Macri, F., Liotta, L., Bonfiglio, R., Stefano, C. De, Ruscica, D., & Aiudis, G. (2013). Ultrasound measurement of reproductive organs in juvenile European sea bass Dicentrarchus labrax. Journal of Fish Biology, 83, 1439–1443.

      [25] McEvoy, F. J., Tomkiewicz, J., Stottrup, J. G., Overton, J. L., McEvoy, C., & Svalastoga, E. (2009). Determination of Fish Gender Using Fractal Analysis of Ultrasound Images. Veterinary Radiology & Ultrasound, 50(5), 519–524.

      [26] Sarode, M. V., & Deshmukh, P. R. (2011). Reduction of Speckle Noise and Image Enhancement of Images Using Filtering Technique. International Journal of Advancements in Technology, 2(1), 30–38.

      [27] Umamaheswari, G., & Vanithamani, R. (2014). An adaptive window hybrid median filter for despeckling of medical ultrasound images. Journal of Scientific & Industrial Research, 73, 100–102.

      [28] Shinde, B., Mhaske, D., Patare, M., & Dani, A. R. (2012). Apply Different Filtering Techniques to Remove the Speckle Noise Using Medical Images. International Journal of Engineering Research and Applications, 2(1), 1071–1079.

      [29] Gupta, R., Gupta, R., & Tyagi, D. K. (2015). Despeckling of Cranial Images Using Wiener Filter. International Journal of Scientific Research and Education, 3(6), 3696–3703.

      [30] Sudeep, P. V., Palanisamy, P., Rajan, J., Baradaran, H., Saba, L., Gupta, A., & Suri, J. S. (2016). Speckle reduction in medical ultrasound images using an unbiased non-local means method. Biomedical Signal Processing and Control, 28, 1–8.

      [31] Breivik, L. H., Snare, S. R., Mirarkolaei, H. N., Steen, E. N., & Solberg, A. H. S. (2014). Multiscale Nonlocal Means method for Ultrasound Despeckling. In International Ultrasonics Symposium (pp. 1324–1327). IEEE.

      [32] Gonzalez, R. C., & Woods, R. E. (2008). Digital Image Processing: Third Edition. Pearson Prentice Hall.

      [33] Kirchner, M., & Fridrich, J. (2010). On Detection of Median Filtering in Digital Images. In Media Forensic and Security II (Vol. 7541). San Jose, California: SPIE Digital Library.

      [34] Ovireddy, S., & Muthusamy, E. (2014). Speckle Suppressing Anisotropic Diffusion Filter for Medical Ultrasound Images. Ultrasonic Imaging, 36(2), 112–132.

      [35] Eskildsen, S. F., Coupe, P., Fonov, V., Manjon, J. V., Leung, K. K., Guizard, N., … Initiative, T. A. D. N. (2012). BEaST: Brain extraction based on nonlocal segmentation technique. NeuroImage, 59, 2362–2373.

      [36] Joel, T., & Sivakumar, R. (2013). Despeckling of Ultrasound Medical Images: A Survey. Journal of Image and Graphics, 1(3), 161–165.

      [37] Tung, K. H., & Raveendran, P. (2009). A Survey of Image Quality Measures. Paper presented at the 2009 International Conference for Technical Postgraduates (TECHPOS), Kuala Lumpur.

      [38] Razak, N. A. A., Madzin, H., Khalid, F., & Mustaffa, M. R. (2017). Gonad Ultrasonography Image Preprocessing for Mahseer (Tor Tombroides). Journal of FisheriesScience.com, 11(3), 26–35.

      [39] Fauci AS, Braunwald E, Kasper DL & Hauser SL (2008), Principles of Harrison’s Internal Medicine, Vol. 9, 17thedn. McGraw-Hill, New York, NY, pp.2275–2304.

      [40] Kim HS & Jeong HS (2007), A nurse short message service by cellular phone in type-2 diabetic patients for six months. Journal of Clinical Nursing 16, 1082–1087.

      [41] Lee JR, Kim SA, Yoo JW & Kang YK (2007), The present status of diabetes education and the role recognition as a diabetes educator of nurses in korea. Diabetes Research and Clinical Practice 77, 199–204.

      [42] McMahon GT, Gomes HE, Hohne SH, Hu TM, Levine BA & Conlin PR (2005), Web-based care management in patients with poorly controlled diabetes. Diabetes Care 28, 1624–1629.

      [43] Thakurdesai PA, Kole PL & Pareek RP (2004), Evaluation of the quality and contents of diabetes mellitus patient education on Internet. Patient Education and Counseling 53, 309–313.

  • Downloads

  • How to Cite

    Asmaa Abd Razak, N., Madzin, H., Khalid, F., & Rina Mustaffa, M. (2018). Speckle Filtering Method in the Gonad Ultrasound Image for Mahseer’s Fish (Tor Tombroides). International Journal of Engineering & Technology, 7(4.31), 15-19. https://doi.org/10.14419/ijet.v7i4.31.23334