Strehl Ratio for Annular Eccentric Circular Aperture with Presence of Seidel Aberrations

  • Authors

    • Farah Mohammed Faisal
    • Sundus Y. Hasan
    2018-12-09
    https://doi.org/10.14419/ijet.v7i4.36.24221
  • Point spread function, optimum balance, eccentric circular aperture, seidel aberrations.
  • Abstract

    In this research the equation of point spread function (PSF) has been derived for annular eccentric aperture optical system which is consisting of circular perture with non-central circular obscuration. The study was done with diffraction limited system and when different 1st and 3rd orders aberrations were present. Also trying to show how the presence of some 1st order errors with some of 3rd order aberrations were affected on Strehl ratio and make a balancing of aberrations which gives in turn a better image.

     

     

  • References

    1. [1] Sharma KK, Optics: principles and applications, Elsevier, (2006).

      [2] Sheppard CJ & Choudhury A, “Annular pupils, radial polarization, and super resolutionâ€, Applied optics, Vol.43, No.22, (2004), pp.4322-4327.

      [3] Dai GM & Mahajan VN, “Zernike annular polynomials and atmospheric turbulenceâ€, JOSA A, Vol.24, No.1, (2007), pp.139-155.

      [4] Mahajan VN & Díaz JA, “Imaging characteristics of Zernike and annular polynomial aberrationsâ€, Applied optics, Vol.52, No.10, (2013), pp.2062-2074.

      [5] Lundström LK, Unsbo P & Gustafsson J, “Off-axis wave front measurements for optical correction in eccentric viewingâ€, Journal of Biomedical Optics, Vol.10, No.3, (2005), pp.034002-1- 034002-7.

      [6] Liu Y & Chen J, “Analysis of eccentric photo refraction by Fourier opticsâ€, Chinese Optics Letters, Vol.5, No.3, (2007), pp.146-148.

      [7] Al-Awsi SMK, “Effect of Optical Eccentricity of Human Eye on Vision Qualityâ€, Journal of Al-Nahrain University-Science, Vol.15, No.1, (2012), pp.55-64.

      [8] Wang C, Bai M & Jin M, “Enhanced optical transmission through double-overlapped annular aperture arrayâ€, Journal of Modern Optics, Vol.59, No.12, (2012), pp.1100-1105.

      [9] Liu SH & Tsai JC, “Auto stereoscopic Eccentric Projection Display with Adjustable Image Sizes and Viewing Zonesâ€, Journal of Display Technology, Vol.12, No.7, (2016), pp.715-720.

      [10] Kessler D, Image quality criteria in the presence of moderately large aberrations, University of Arizona: USA, (1981).

      [11] Mahajan VN, Optical Imaging and Aberrations, Part II: Wave Diffraction Optics, 2nd ed. SPIE, (2011).

      [12] Sheppard CJ, Maréchal condition and the effect of aberrations on Strehl intensity. Optics letters, Vol.39, No.8, (2014), pp.2354-2357.

      [13] Alonso MA & Forbes G, Strehl ratio as the Fourier transform of a probability density of error differences. Optics letters, Vol.41, No.16, (2016), pp.3735-3738.

      [14] Mafusire C & Krüger TP, “Strehl ratio and amplitude-weighted generalized orthonormal Zernike-based polynomialsâ€, Applied optics, Vol.56, No.8, (2017), pp.2336-2345.

  • Downloads

  • How to Cite

    Mohammed Faisal, F., & Y. Hasan, S. (2018). Strehl Ratio for Annular Eccentric Circular Aperture with Presence of Seidel Aberrations. International Journal of Engineering & Technology, 7(4.36), 674-677. https://doi.org/10.14419/ijet.v7i4.36.24221

    Received date: 2018-12-18

    Accepted date: 2018-12-18

    Published date: 2018-12-09