Performance Based Economical Design of Hybrid Filter and APFC to Improve the Power Quality of Industry

  • Authors

    • Karuna Nikum
    • Abhay Wagh
    • Rakesh Saxena
    • Bharat Mishra
    2018-12-19
    https://doi.org/10.14419/ijet.v7i4.41.24292
  • Automatic power factor correction, Active power filter, harmonics, hybrid power filter, Power quality, power factor, passive power filters.
  • Abstract

    The aim of this paper to analyze the power quality (PQ) and provide a cost effective solution to mitigate the harmonics and improve the power factor (PF) in industry. The detailed harmonic analysis and monitoring performed to rectify the PQ issues.  In this paper automatic power factor correction (APFC) for power factor improvement and hybrid power filter (HPF)which is combination of (APF) and passive Power filter (PPF) has been proposed. The design of active filter by two different control scheme has been proposed and compared. The modelling and simulation has been carried out to verify proposed analysis in MATLAB Simulink environment individually. To make the proposed solution cost-effective, combination of PPF only  for fifth harmonic frequency and APF for other remaining harmonic frequencies has been used. The HPF reduces the cost as well as rating of the APF. The cost and rating of APF is also compared with and without passive filter of the system.

     

     
  • References

    1. [1] A. Hamadi, S. Rahmani, K. Al-Haddad, A hybrid passive ï¬lter conï¬guration for VAR control and harmonic compensation, IEEE Trans. Ind. Electron, Vol. 57, No.7, 2010, pp.2419–2434.

      [2] M.S. Hamad, M.I. Masoud, B.W. Williams, Medium-voltage 12-pulse converter: Output voltage harmonic compensation using a series APF, IEEE Trans. Ind. Electron, Vol. 61, No.1, 2014, pp. 43–52.

      [3] A.F. Zobaa, M.M. Abdel Aziz, S.H.E Abdel Aleem, Comparison of shunt-passive and series-passive ï¬lters for DC drive loads, Elect. Power Comp. Syst., Vol.38 No.3, 2010, pp. 275–291.

      [4] D. Kumar, F. Zare, Harmonic analysis of grid connected power Electronic systems in Low voltage distribution network, IEEE journal of emerging and selected topics in power electronics, Vol. 4, No.1, 2016, pp.70-78.

      [5] J.C. Das, Passive ï¬lters-potentialities and limitations, IEEE Trans. Ind. Appl., Vol. 40, No.31 2004, pp.232–241.

      [6] A.B. Nassif, W. Xu, and W. Freitas, An investigation on the selection of ï¬lter topologies for passive ï¬lter applications, IEEE Trans. Power Del., Vol. 24, No. 3, 2009, pp.1710-1718.

      [7] Y. Xiao , J. Zhao, S. Mao, Theory for the design of C-type ï¬lter, in Proc. 11th Int. Conf. Harmonics Quality Power (ICHQP), Lake Placid, NY, USA, 11–15(2015).

      [8] Richards. G.G, Tan. O.T, Klinkhachorn. P, Santoso. N.I: Cost constrained power factor optimization with source harmonics using LC compensators, IEEE Trans. Ind. Electron., Vol. 34, No.2,1987, pp.266–270.

      [9] S.H.E Abdel Aleem, A.F. Zobaa, M.M. Abdel Aziz, Optimal C-type passive ï¬lter based on minimization of the voltage harmonic distortion for nonlinear loads, IEEE Trans. Ind. Electron., Vol. 59, No. 1, 2012, pp. 281–289.

      [10] L. Sainz and J. Balcells, Harmonic interaction influence due to current source shunt ï¬lters in networks supplying nonlinear loads, IEEE Trans. Power Del., Vol. 27, No.3, 2012, pp. 1377–1385.

      [11] S.H.E Abdel Aleem and A.F. Zobaa, Different design approaches of shunt passive harmonic ï¬lters based on IEEE Std. 519-1992and IEEE Std. 18-2002, Recent Pat. Elect. Eng., Vol. 6, No.1, 2013, pp. 68–75(2013).

      [12] A. Medina-Rios and H. A. Ramos-Carranza, An Active Power Filter in Phase Coordinates for Harmonic Mitigation, in IEEE Transactions on Power Delivery, vol. 22, no. 3, pp. 1991-1993, July 2007.

      [13] B. Singh, K. Al-Haddad and A. Chandra, "A review of active filters for power quality improvement," in IEEE Transactions on Industrial Electronics, Vol. 46, No. 5, pp. 960-971, Oct 1999.

      [14] C. Liu, Y. He, K. Dai and Y. Kang, Industrial power distribution system harmonic resonance problem and solution with shunt active power filter, IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society, Beijing, 2017, pp. 1243-1248.

      [15] H. Fujita and H. Akagi, A practical approach to harmonic compensation in power systems-series connection of passive and active filters,in IEEE Transactions on Industry Applications, vol. 27, no. 6, pp. 1020-1025, Nov.-Dec. 1991.

      [16] IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems - Redline," in IEEE STD 519-2014 (Revision of IEEE Std 519-1992) - Redline, vol., no., pp.1-213, June 11 2014.

  • Downloads

  • How to Cite

    Nikum, K., Wagh, A., Saxena, R., & Mishra, B. (2018). Performance Based Economical Design of Hybrid Filter and APFC to Improve the Power Quality of Industry. International Journal of Engineering & Technology, 7(4.41), 24-30. https://doi.org/10.14419/ijet.v7i4.41.24292

    Received date: 2018-12-18

    Accepted date: 2018-12-18

    Published date: 2018-12-19