Investigation on the use of cold formed perforated steel sections as columns and purlins
-
2018-09-22 https://doi.org/10.14419/ijet.v7i4.5.25066 -
ANSYS, Buckling, C and Z Section, Cold Formed Steel, Perforation. -
Abstract
Perforations are required in columns and purlins of a trussed building for making connections, for fixing electrical fixtures etc. An inves- tigation was undertaken to study the effect of perforations in cold-formed C and Z sections used as columns and purlins. For this purpose, finite element model was developed using ANSYS software. Six different shapes of perforations were considered to investigate the shape that gives maximum buckling load. The perforation pattern which is optimum for the individual section was applied to frames and then to the building and optimum type of perforation is suggested. Buckling loads of frames and building with and without perforation was done separately and results were compared. By considering perforations with equal area, linear buckling analysis was done and stress pattern around perforation was studied. Even though the area reduction was equal, differently shaped perforations gave different buckling load. In this case, stress concentration has an important role; buckling load is higher for the shape with least stress concentration.
Â
Â
Â
-
References
[1] M.P.Kulatunga, M.Macdonald, J.Rhodes, D.K.Harrison, Load capacity of cold-formed column members of lipped channel cross-section with perforations subjected to compression loading– Part I: FE simulation and test results, Elsevier, Thin-Walled Structures 80 2014: 1–12.
[2] K. Devarajan, K. Prakash Marimuthu and Dr. Ajith Ramesh, FEM Analysis of Effect of Rolling Parameters on Cold Rolling Process, Bonfring International Journal of Industrial Engineering and Management Science, Vol. 2, No. 1, March 2012.
[3] Jin Ying Ling, Shin Lin Kong, Fatimah De' nan, Numerical study of buckling behavior of cold-formed C- channel steel purlin with perforation, Elsevier, Procedia Engineering 125 2015: 1135 – 114.
[4] M.P. Kulatunga, M.Macdonald, Investigation of cold- formed steel structural members with perforations of different arrangements subjected to compression loading, Thin-Walled Structures 67 2013: 78–87.
[5] K. Sivakumaran, Some studies on cold-formed steel sections with web openings, 9th International specialty conference on cold-formed steel structures, Rolla: University of Missouri; 1988:513-527.
[6] MY Shan, R a Laboube, Behavior of web elements with openings subjected to bending, shear and the combination of bending and shear, Missouri s&t: 1994.
[7] Cristopher D. Moen, B.W. Schafer, Experiments on cold-formed steel columns with holes, Elsevier-thin walled structures: 2008.
[8] Shahabeddin Torabian, David.C.Fratamico, Benjamin.Schafer, Experimental response of cold- formed steel Zee-section beam-columns, Elsevier, Thin-Walled Structures 98: 2016: 496–517.
[9] Hélder D.Craveiro, JoãoPaulo, C.Rodrigues n, LuÃsLaÃ, Buckling resistance of axially loaded cold-formed steel columns, Elsevier-Thin-WalledStructures 106: 2016: 358–375.
[10] Cristopher D. Moena, B.W. Schafer b, Elastic buckling of cold-formed steel columns and beams with holes, Elsevier –engineering structures: 2009.
[11] K. Tsavdaridis, C. D Mello, Finite element investigation of perforated steel beams with different web opening configurations, Sixth International Conference on Advances in Steel Structures and Progress in Structural Stability and Dynamics, 2009: 213-220.
[12] Shanmugam NE, Dhanalakshmi M, Design for openings in cold-formed steel channel stub columns. Thin-Walled Str: 2001; 39:961–81.
[13] Kulatunga M, Macdonald M, Investigation of cold- formed steel structural members with perforations of different shapes subjected to compression loading. In: Proceedings of the sixth international conference on couple of instabilities in metal structures.2012.
[14] IS SP 38-1987 -Handbook Of Typified Designs For Structures With Steel Roof Trusses (With And Without Cranes) (Based On Is Codes).
[15] IS 875 (Part 1, 2 & 3): Code of Practice for Design Loads (Other than Earthquake) For Buildings and Structures. Part 1: Dead Loads--Unit Weights of Building Materials and Stored Materials. Part 2: Imposed Loads. Part 3: Wind Loads.
[16] IS 801: Code of Practice for Use of Cold-Formed Light Gauge Steel Structural Members in General Building Construction.
-
Downloads
-