Effect of the Rib Depth to the Overall Beam Depth Ratio in the Lightweight One-Way Ribbed Slabs

  • Authors

    • Taif A. Abdulkareem
    • Ashraf A. Alfeehan
    2018-11-28
    https://doi.org/10.14419/ijet.v7i4.20.26239
  • ANSYS, lightweight, micro-reinforcement, ribbed slab, load-deflection.
  • Abstract

    The ribbed slabs provide a lighter and stiffer slab than an equivalent traditional slab with minimizing the total volume of the materials. Four one-way lightweight concrete panels, including one flat and three ribbed panels were cast and tested under two-point load as simply supported up to the failure. The main investigated variable is a ratio of the rib depth (d) to the overall beam depth (h). All the panels have the same concrete volume and the same steel reinforcement ratio. Also, the width of the rib is equal to the slab thickness as a constraint condition in all the panels. Data were recorded at the loading stages to determine the load capacity and the deflection. A nonlinear finite element analysis carried out by using ANSYS-15 software program to analyze the panels and to verify the results. Increase the (d/h) ratio improved the structural behavior by increase the carrying load capacity and reduces the deflection to a certain limit. Compatibility results have been obtained between the numerical and experimental work.

     

     

     
  • References

    1. [1] Yam, L.C.P., "Design of Composite Steel-Concrete Structures", Surry University Press, London, (1981), 168 p.

      [2] De Oliveira, W. M. Souza., and T. R. G. Caetano, "Shear Strength of Reinforced Concrete One-way Ribbed Slabs.", Ibracon structures and materials journal, Vol.4, Issue 5, (2014).

      [3] Abdul-Wahab, H. M., and M. H. Khalil, "Rigidity and Strength of Orthotropic Reinforced Concrete Waffle Slabs.", Journal of structural engineering, Vol.126, Issue 2, (2000), pp. 219-227.

      [4] Olawale, A. J and A. G. Ayodele, "A Comparative Study on the Flexural Behaviour of Waffle and Solid Slab Models When Subjected to Point Load" Journal of civil engineering and architecture, Vol.4, Issue 5, (2014).

      [5] Skoyles, E.R., Bardhan-Roy, K., “A Comparative Study of Economics of “Lightweight Structural Concrete Floor Slabs in Buildingâ€, The international journal of lightweight concrete, Vol.1, No.1, (1979), pp.9-27.

      [6] Ali, M. A., “The Possibility of Produce Self Compacted Polystyrene Concreteâ€, Journal of engineering and development, Vol. 16, No.4, (2012), pp. 1-15.

      [7] Slate, F. O., Nilson, A. H., and Martinez, S., “Mechanical Properties of High-Strength Lightweight Concreteâ€, ACI Journal, Vol. 83, No. 4, (1986), pp. 606-613.

      [8] ACI Committee 213R-03, "Guide for Structure Lightweight-Aggregate Concrete", American Concrete Institute, USA, (2003), pp.1-37.

      [9] ACI Committee 318, "Building Code Requirements for Structural Concrete (ACI 318-M14)", American Concrete Institute, USA, (2014).

      [10] Structural Technologies "DUCON® Micro-Reinforced Concrete Armoring System, http://www.structuraltechnologies.com.au.

      [11] ANSYS, "ANSYS Help", version 15.0, Copyright (2013).

  • Downloads

  • How to Cite

    A. Abdulkareem, T., & A. Alfeehan, A. (2018). Effect of the Rib Depth to the Overall Beam Depth Ratio in the Lightweight One-Way Ribbed Slabs. International Journal of Engineering & Technology, 7(4.20), 438-442. https://doi.org/10.14419/ijet.v7i4.20.26239

    Received date: 2019-01-20

    Accepted date: 2019-01-20

    Published date: 2018-11-28