A Study on the Prism Sheet Applied Double-Skin Facade for Saving Lighting Energy

  • Authors

    • Minwoo JANG
    • Younghoon BYUN
    • Ri RYU
    • Yongseong KIM
    https://doi.org/10.14419/ijet.v8i1.4.26314
  • Prism sheet, Double-Skin Façade, Illuminance, Performance Evaluation
  • With the recent increase in the use of lighting energy in the building sector and as skyscrapers are developed with glass envelopes, research on reducing lighting energy consumption by introducing natural light into the building is increasing. However, natural lighting systems have limited lighting energy reduction efficiency in buildings due to the application of operating technologies in order to reduce the lighting energy and improve the lighting performance. Therefore, the purpose of this study is to propose a double-skin facade for reducing lighting energy by using prism sheets, and to verify its effectiveness through the performance evaluation using a full-scale testbed. The conclusion is as follows. 1) This study derived the optimal variables for the double-skin without prism sheets (Case 1), double-skin with prism sheets on the outer skin of the cavity (Case 2), and the double-skin with prism sheets on the inner skin of the cavity (Case 3). 2) With the optimal variables, Case 3 was able to reduce lighting energy by 25.93% and 1.24%, respectively, compared to Case 1 and Case 2. By using the diffusion principle of the refraction of prisms sheets, the lighting energy reduction and the lighting performance were improved compared to the conventional double-skin. In addition, considering the reduction of lighting energy, the efficiency is considered to be higher than the conventional double skin. 3) Based on the optimal attachment angle of the prism sheet derived for each case, Case 3 was able to improve the uniformity by 68.94% and 2.26% in summer, and 55.0% and 6.90% in the mid-season, respectively, compared to Case 1 and Case 2. However, as the application of prism sheets reduces the uniformity in winter, it is preferable to remove the prism sheets during winter. This problem can be resolved by attaching and detaching the prism sheets or by using a double-skin window with blinds made of prism sheet material.

     

  • References

    1. [1] Jang M, Byun Y, Ryu R, Kim Y (2018), A Basic Study on the Application of Prism Sheets to Double-Skin Facades to Improve Indoor Light Environments, International Journal of Computer-aided Mechanical Design and Implementation, Vol. 4, No. 1, pp.7-12

      [2] Heo D, Lee H Seo, J, Kim Y (2015), Daylight Performance Evaluation of Light-shelf according to the Reflectivity – Focused on the Residing space-, KIEAE Journal, Vol.15, No.3, pp.49-56

      [3] Kim DK, Yoon KC, Kang JS, Kim KS (2011), An Experimental Study on Indoor Thermal Characteristics in accordance with the Use of Windows and Blinds in Double Skin Facade in Summer, Journal of the Korean Solar Energy Society, Vol.31, No.1, pp.59-67

      [4] Song CH, Kim T, Leigh SB (2015), The Analysis on the Variation of the Ventilation Rates by Wind Pressure and Temperature Difference between Indoor and Outdoor in the Multi-Story Type Double Skin Facade applied to the Office Building, KIEAE Journal, Vol.15, No.2, pp.123-131.

      [5] Lim TS, Kang SM (2015), Evaluation of Seasonal Daylighting Performance according to Window Compositions of Double Skin Facades, Journal of the Korean Institute of Interior Design, Vol.24, No.4, pp.91-98

      [6] Kim KS Lee, EJ (2002), Daylighting System Using Fresnel & Prismatic Films, JOURNAL OF THE ARCHITECTURAL INSTITUTE OF KOREA Planning & Design, Vol.18, No.7, pp.177-184

      [7] Kim WS, Jeong HJ, Chun W, Han HJ, Lim SH (1997), A study on the utilization status and technical development of solar tracking daylighting systems, JOURNAL OF THE ARCHITECTURAL INSTITUTE OF KOREA, Vol.13, No.2, pp:139-149

      [8] Jeong SA (2017), Natural light system that uses sunlight as illumination, KIAEBS Journal, Vol.11, No.2, pp:43-50

      [9] Seo KB, Song KD (2016), The Development of Design Tools of Daylight Duct Systems for Underground Spaces, Journal of Energy Engineering, Vol.25, No.4, pp:62-73

      [10] Kim HS (1996), A Study on the Developement of Light Duct System for Utilization of Daylighting on Underground Space, Journal of the Korean Solar Energy Society, Vol.16, No.3, pp:37-45

      [11] http://www.ihyunchang.co.kr/services/energy.html

      [12] http://solarinnovation.co.kr/system/sub01_2.htm

      [13] Jeong H, Kim W, Kim Y, Han HJ, Chun W (2017), Electric Lighting Energy Saving Through the Use of A Fresnel Lens Based Fiber-optic Solar Lighting System - Simulation and Measurements -, Journal of the Korean Solar Energy Society, Vol.37, No.3, pp:1-12

      [14] Kim Y, Kim WS, Jeong HJ (2017), Chun W, Performance Analysis on Solar Tracking Daylighting Systems Using Different Types of Solar Collectors - Parabolic Dish vs. Fresnel Lens -, Journal of the Korean Solar Energy Society, Vol.37, No.1, pp:39-45

      [15] Jeong HG, Han SB, Jung BM, Lee EJ (2002), A Study on Light Guide Luminaire Design using Prismatic Film, KIEAE Journal, Vol.2, No.2, pp:33-38

      [16] Park BY, Choi CH (2011), A Study on Daylighting Performance of an Inner Court with Reflecting Mirror System, Journal of the Korean Solar Energy Society, Vol.31, No.4, pp:112-121

      [17] Park YC (2009), Compensation of Sun Tracking Error caused by the Heliostat Geometrical Error through the Canting of Heliostat Mirror Facets, Journal of the Korean Solar Energy Society, Vol.29, No.6, pp:22-31

      [18] Jeon G, Lee H, Seo J, Kim Y (2016), Performance Evaluation of Light-Shelf based on Light Enviorment and Air Conditioner Enviorment, KIEAE Journal, Vol.16, No.5, pp:47-55

      [19] Park MY, O SD (2014), A Study on the Survey of Daylighting Hybrid Illumination System Performance using Building Envelope Attached Type, Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, Vol.8, No.2, pp:65-72

      [20] Hwang DS, Lee KH (2010), A Study on the Evaluation on Natural Lighting Performance in Accord with the Installation of Sunblind at Apartment House Extended Balcony Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, Vol.4, No.2, pp:69-74

      [21] Kim JT, Chung YG, Yeo IH (1997), Daylighting Performance Evaluation on Toplit Atrium with Louvers by Scale Model Experiment, JOURNAL OF THE ARCHITECTURAL INSTITUTE OF KOREA, Vol.13, No.10, pp:205-212

      [22] Seong-Lyong Kim, Insun Kim, “Development of a solar flux model for thermal load prediction of a launch vehicleâ€, Journal of The Korean Society for Aeronautical and Space Sciences, VoL.35, No.9, (2007), pp:826-835

      [23] Park SK, Yu IH, Son WT, Shin JW, Jeong YH, Kim YM (2011), A Study on Daylight-factor condition for using Daylighting system, The Society of Air-Conditioning and Refrigerating Engineers of Korea, pp:367-372

      [24] Shin SY, Seo DH (2015), Evaluation of Available Potential Daylighting in Korea’s Urban, The Society of Air-Conditioning and Refrigerating Engineers of Korea, pp:497-498

      [25] Choi DH, Jo JH, Seok HT, Yeo MS, Kim KW (2005), Planning the Blind Position Considering Thermal Performance in the Intermediate Space of Double - Skin Façade, Korean Journal of Air-Conditioning and Refrigeration Engineering, VoL.17, No.7, pp:620-629

      [26] Ryu, R, Ji CG, Kim, YS (2013), Study of Window-Type Double Skin System Using PCM: Focusing on Energy Reduction for Heating and Cooling, JOURNAL OF THE ARCHITECTURAL INSTITUTE OF KOREA Planning & Design, VoL.29, No.4, pp.227-234

      [27] Chung HK, Chung KS, Lee YJ, Shin SC, Kim YI (2012), A Study on Analysis Method for Performance Evaluation of Double-leaf facade of Office Building, Journal of Energy Engineering, VoL.21, No.2, pp:168-178

      [28] Lee BY, Kim YS (2000), A Study on environmental performance of double-skin system, ARCHITECTURAL INSTITUTE OF KOREA, VoL.20, No.2, pp:913-916

      [29] Seok HT (2003), Performance Evaluation of Double Skin Facade System, The Society of Air-Conditioning And Refrigerating Engineers Of Korea, pp:243-252

      [30] Eom JW, Kim JK, Huh JH, Cho S (2001), An Experimental Study on the Thermal Environment of the Double Skin Building System, ARCHITECTURAL INSTITUTE OF KOREA, VoL.21, No.2, pp:977-980

      [31] Jeong JM, Kim JH, Shin MG, Lee MR, Chung JY, Jeong HS, Kim JS, Kang JG, Hong BH, Cho GS (2007), Luminance Normalization of Optical Sheets in a Backlight Unit for LCD-TVs, The Korean Vacuum Soiety, Applied Science and Convergence Technology, VoL.16, No.6, pp:424-432

      [32] Ji CK, Lee JW, Kim SK (1993), A Study on the revision of Korea Industrial Standards Illumination Standard, The Korean Institute of Illuminating and Electrical Installation Engineers, VoL.7, No.6, pp:14-24

      [33] Lee HW, Rogers KE, Seo JH, Kim YS (2015), A Study on Lighting Performance Evaluation of Light-Shelf using Crystal Face, The Society Of Air-Conditioning And Refrigerating Engineers Of Korea, VoL.27, No.80, pp:395-401

      [34] Chae WR, Lee HW, Seo SH, Kim YS (2014), Evaluation of Lighting Performance of Mixed Type Light-shelf in Residential Space According to Angular Variations, The Society of Air-Conditioning and Refrigerating Engineers of Korea, VoL.26, No.9, pp:424-433

  • Downloads

  • How to Cite

    JANG, M., BYUN, Y., RYU, R., & KIM, Y. (2019). A Study on the Prism Sheet Applied Double-Skin Facade for Saving Lighting Energy. International Journal of Engineering & Technology, 8(1.4), 579-587. https://doi.org/10.14419/ijet.v8i1.4.26314