Energy Monitoring System Using Zigbee and Arduino

  • Authors

    • R. Govindarajan
    • Dr. S.Meikandasivam
    • Dr. D.Vijayakumar
    2018-11-30
    https://doi.org/10.14419/ijet.v7i4.28.28182
  • Zigbee communication, Energy Monitoring System (EMS), Arduino.
  • Abstract

    The proposed concept provide a low cost Energy Monitoring System (EMS) using ZigBee wireless Communication with Arduino controller. It is used to monitor the electrical real time parameters without any wired network. In this paper we discussed about zigbee versus Arduino interfacing technique, which is used to reduce the more number of coding and get the energy meter reading in less range of delay time. The proposed concept is developed  in order to achieve energy saving and provide the awareness to the residential, commercial and industrial consumer about the power utilization day to day with strong communication protocol and  arduino controller with simple embedded coding. The objective of the system is, providing fast power communication between distribution and consumer with low cost and easy to interface.

     


  • References

    1. [1] Bureau of Energy Efficiency, Ministry of Power, Government of India.

      [2] M.G. Lee, Y.K. Park, K.K. Jung, J.J. Yoo, “Design of smart energy monitoring system for green IT lifeâ€, International Journal of Computer and Information Engineering, June, 2012.

      [3] Liu Yanfei, Wang Cheng, Qiao Xiaojun, Zhang Yunhe, Yu chengbo,"An Improved Design of ZigBee Wireless Sensor Network", IEEE proceedings of ICCST, 2009.

      [4] Yang Li, Ji Maorong, Gao Zhenru, Zhang Weiping, Guo Tao, "Design of Home Automation System Based on ZigBee Wireless Sensor Network", Proceedings of ICISE, 2009.

      [5] Shah, P., Shaikh, T., Ghan, K., Shilaskar, S., "Power Management Using ZigBee Wireless Sensor Network", Proceedings of ICETET, 2008.

      [6] H. Park, J. Burke, and M. B. Srivastava, “"Design and Implementation of a Wireless Sensor Network for Intelligent Light Control,†"International Conference on Information Processing in Sensor Networks, 2007.

      [7] G. Song, F. Ding, W. Zhang, and A. Song, “A wireless power outlet system for smart homes,†IEEE Transactions on Consumer Electronics, vol. 54, no. 4, pp. 1688-1691, November 2008.

      [8] Han, J. and Lee, H. and Park, K.R., “Remote-controllable and energysaving room architecture based on ZigBee communicationâ€, IEEE Transactions on Consumer Electronics (TCE), 2009.

      [9] Kim, W.H. and Lee, S. and Hwang, J., “Real-time Energy Monitoring and Controlling System based on ZigBee Sensor Networksâ€, Elsevier Procedia Computer Science(PCS), 2011.

      [10] Bai, Y.W. and Hung, C.H., “Remote power On/Off control and current measurement for home electric outlets based on a low-power embedded board and ZigBee communicationâ€, IEEE Transaction, 2008.

      [11] Cheng, J.Y. and Hung, M.H. and Chang, J.W., “A zigbee-based power monitoring system with direct load control capabilitiesâ€, IEEE International Networking, Sensing and Control (INSC),2007.

      [12] Lien, C.H. and Bai, Y.W. and Lin, M.B., “Remote-controllable power outlet system for home power managementâ€, IEEE Transactions on Consumer Electronics (TCE), 2007.

      [13] Luan, S.W. and Teng, J.H. and Chan, S.Y. and Hwang, L.C., “Development of a smart power meter for AMI based on ZigBee communicationâ€, IEEE International Conference on Power Electronics and Drive Systems, 2009.

      [14] M. Xu, L. Ma, F. Xia, T. Yuan, J. Qian, and M. Shao, “"Design and Implementation of a Wireless Sensor Network for Smart Homes,†ICSSE 2011 Symposia and Workshops on Ubiquitous, Autonomic and Trusted Computing, 2010.

      [15] IEEE 802.15.4 standard specification, The physical layer and media access control for low-rate wireless personal area networks, 2009.

      [16] S. Arun; Dr, Sidappa Naidu, “Design and Implementation of Automatic Meter Reading System Using GSM, ZIGBEE through GPRS†in international journal of advanced research in computer science software engineering , 2012.

      [17] Young Hoon Lim, Moon Suk Chain, Jong Mock Baek, Sang-Yeom Lee “An An Efficient Home Energy Management System Based on Automatic Meter Reading†in IEEE International Symposium on Power Line Communication, 2011.

      [18] Chih-Hung Wu, “Design of a Wireless ARM-Based Automatic Meter Reading and Control Systemâ€, Power Engineering Society General Meeting, 2004. IEEE 6-10, Vol.1, pp.957-962, June 2004.

      [19] “ZigBee The Choice for Energy Management and Efficiency†presented by ZigBee Alliance, 2007

      [20] Takeshi N, An Electric Power Energy Monitoring System in Campus using an Internet. Member, IEEE.83(7)705-722, 2006.

      [21] “ZigBee Vision for the Homeâ€, ZigBee Wireless Home Automation, by ZigBee Alliance, 2006.

      [22] G. Song, F. Ding, W. Zhang, and A. Song, “A wireless power outlet system for smart homes,†IEEE Transactions on Consumer Electronics, vol. 54, no. 4, pp. 1688-1691, 2008.

      [23] C. H. Lien, C. H. Lin, Y. W. Bai, M. F. Liu, and M. B. Lin, “Remotely controllable outlet system for home power management,†IEEE Tenth International Symposium on Consumer Electronics, pp. 1-6, 2006.

      [24] LONG Yuxiang, ZHANG Jing, DAI Yuxin, “Design of Concentrator Based on ZigBee in Wireless Meter Reading System,â€Lower electrical apparatus, Beijing, 2007.

      [25] C. H. Lien, Y. W. Bai, and M. B. Lin, “Remote-controllable power outlet system for home power management,†IEEE Transactions on Consumer Electronics, vol. 53, no. 4, pp. 1634-1641, 2007.

      [26] C. H. Lien, H. C. Chen, Y. W. Bai, and M. B. Lin, “Power monitoring and control for electric home appliances based on power line communication,†IEEE Instrumentation and Measurement Technology Conference, pp. 2179-2184, 2008.

      [27] J. Han, H. Lee, and K. Park, “Remote-controllable and energy-saving room architecture based on ZigBee communication,â€IEEE Transactions on Consumer Electronics, vol. 55, no. 1, pp. 264-268, 2009.

      [28] W. S. Lee and S. H. Hong, “KNX – ZigBee Gatway for home automation,†IEEE International Conference on Automation Science and Engineering, pp. 750-755, 2008.

      [29] Goswami A, Bezboruah T, Sarma KC, Design of an Embedded System for Monitoring and Controlling Temperature and Light, International journal of Electron. Eng. Res., 27-36, 2009

      [30] Mehroze A, Barry D, Smart Demand-Side Energy Management Based on Cellular Technology - A way towards Smart Grid Technologies in Africa and Low Budget Economies. IEEE .Nairobi, Kenya, pp.1-6, 2009.

      [31] Cisco Outlines Strategy for Highly Secure, 'Smart Grid' Infrastructure, Cisco News. Newsroom.cisco.com, 2011.

      [32] IEEE, conference drive smart grids. Eetimes.com, 2011.

      [33] Smart Grid and Renewable Energy Monitoring Systems, SpeakSolar.org, 2010.

      [34] F.R. Yu, P. Zhang, W. Xiao, and P. Choudhury, “Communication Systems for Grid Integration of Renewable Energy Resources,†IEEE Network, vol. 25, no. 5, pp. 22-29, 2011.

      [35] [Ieee802.11-PSM] IEEE 802.11 PSM Standard. Power Management for Wireless Networks. Section 11.11.2.

      [36] Holger Karl, An Overview of Energy-Efficiency Techniques for Mobile Communication Systems, TKN Technical Reports Series. Technische Universitaet Berlin.

      [37] H.G. Rodeny Tan, C.H. Lee, V.H Mok, “Automatic power meter reading system using GSM networkâ€, The 8th International Power Engineering Conference, 2007.

      [38] Muhammad Fajri Bayu Anbya, Muhammad Salehuddin, Sutanto Hadisupadmo, Edi Leksono , “Wireless Sensor Network For Single Phase Electricity Monitoring System via ZigBee Protocol†IEEE Conference on Control, Systems and Industrial Informatics (ICCSII), Indonesia, 2012.

      [39] Ashna.k, Sudhish N George, “GSM Based Automatic Energy Meter Reading System with Instant Billingâ€, International Conference on Automation, Computing, Communication, Control and Compressed Sensing,2013.

      [40] Chaitanya Kulkarni, Pratik Paliwal, Sayali Patkar, “Wireless Sensor Network Using ZigBee†International Conference on Electrical, Electronics & Computer Science Engineering, 2017.

  • Downloads

  • How to Cite

    Govindarajan, R., S.Meikandasivam, D., & D.Vijayakumar, D. (2018). Energy Monitoring System Using Zigbee and Arduino. International Journal of Engineering & Technology, 7(4.28), 608-611. https://doi.org/10.14419/ijet.v7i4.28.28182

    Received date: 2019-03-03

    Accepted date: 2019-03-03

    Published date: 2018-11-30