Low Cost Monitoring System of Ground Reaction Force during Normal Gait Cycle for Motion Control and Analysis of Active Ankle Foot Orthosis
-
https://doi.org/10.14419/ijet.v7i4.26.28568 -
Ankle Foot Orthosis, Ground Reaction Force, Real Time Measurement, Gait Phase Detection, Rehabilitation -
Abstract
Human gaits are complicated motion where it involves synergy of muscle coordination, timing, and balance. Many people are unable to walk with normal gait pattern due to neuromuscular disorder. In order to support the weakness muscle, Active Ankle Foot Orthosis (AAFO) device is developed to provide permanent assistance and control the motion of the foot from being dragged during walking. One of the challenges that researchers has to face with the development of AAFO is providing an efficient transmission and producing continuous and smooth gait cycle. This paper proposes a real time gait phase detection system to control AAFO for rehabilitation and assist ankle motion. Real-time gait phase is obtained by measuring ground reaction force (GRF). The proposed system consists of AAFO equipped with ball screw actuator that provides direct assistance to control ankle joint during dorsiflexion and plantarflexion motion. Three force sensors were embedded insole and an encoder was attached at the ankle joint. The developed control algorithm shows that the real-time GRF measurement has the ability to enhance the AAFO functional performance and improve patient’s gait.
Â
Â
-
References
[1] M. N. A. Bin Ab Patar, T. Komeda, and J. Mahmud, “Force assisted hand and finger device for rehabilitation,†in 1st International Symposium on Technology Management and Emerging Technologies (ISTMET), 2014, pp. 133–138.
[2] A. M. F. Barela et al., “Ground reaction forces during level ground walking with body weight unloading,†Brazilian Journal of Physical Therapy, 2014.
[3] M. G. Mataee, M. T. Andani, and M. Elahinia, “Adaptive ankle-foot orthoses based on superelasticity of shape memory alloys,†Journal of Intelligent Material Systems and Structures, 2015.
[4] A. Patar, N. Jamlus, K. Makhtar, J. Mahmud, and T. Komeda, “Development of Dynamic Ankle Foot Orthosis for Therapeutic Application,†Procedia Engineering, vol. 41, pp. 1432–1440, 2012.
[5] D. A. Jacobs, J. R. Koller, K. M. Steele, and D. P. Ferris, “Motor modules during adaptation to walking in a powered ankle exoskeleton,†Journal of NeuroEngineering and Rehabilitation, 2018.
[6] G. M. Gu, S. Kyeong, D. S. Park, and J. Kim, “SMAFO: Stiffness modulated Ankle Foot Orthosis for a patient with foot drop,†in IEEE International Conference on Rehabilitation Robotics, 2015.
[7] R. S. Hall, G. T. Desmoulin, and T. E. Milner, “A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force,†Journal of Biomechanics, 2008.
[8] N. M. Nor Adnan, M. N. A. Ab Patar, H. Lee, S. I. Yamamoto, L. Jong-Young, and J. Mahmud, “Biomechanical analysis using Kinovea for sports application,†in IOP Conference Series: Materials Science and Engineering, 2018.
[9] M. N. A. Bin Ab Patar, M. H. Mohd Ramli, J. Mahmud, and A. H. Yusof, “Efficacy and Safety Testing of a New Biologically Based Design Ankle Foot Orthosis in Healthy Volunteer,†Applied Mechanics and Materials, vol. 110–116, no. 1–7, pp. 1953–1957, Oct. 2011.
[10] H. Yeom and Y. H. Chang, “Autogenic EMG-controlled functional electrical stimulation for ankle dorsiflexion control,†Journal of Neuroscience Methods, 2010.
[11] A. Hamid, M. N. A. A. Patar, and M. A. Ayub, “Force Sensor Detection and Performance Evaluation of New Active System Ankle Foot Orthosis,†Procedia Engineering, vol. 41, pp. 510–515, 2012.
[12] S. Hussain, P. K. Jamwal, M. H. Ghayesh, and S. Q. Xie, “Assist-as-needed control of an intrinsically compliant robotic gait training orthosis,†IEEE Transactions on Industrial Electronics, 2017.
[13] D. A. Jacobs and D. P. Ferris, “Estimation of ground reaction forces and ankle moment with multiple, low-cost sensors,†Journal of NeuroEngineering and Rehabilitation, 2015.
[14] M. N. A. Bin Ab. Patar, M. Mali, M. H. Mohd Ramli, A. K. Makhtar, and J. Mahmud, “Simulation and performance evaluation of a new type of powered Dynamic Ankle Foot Orthosis,†2011 IEEE Colloquium on Humanities, Science and Engineering, no. Chuser, pp. 167–171, 2011.
[15] D. Sanz-Merodio, M. Cestari, J. C. Arevalo, X. A. Carrillo, and E. Garcia, “Generation and control of adaptive gaits in lower-limb exoskeletons for motion assistance,†Advanced Robotics, 2014.
[16] M. N. A. Ab Patar, A. F. Said, J. Mahmud, A. Majeed, and M. A. Razman, “System Integration and Control of Dynamic Ankle Foot Orthosis for Lower Limb Rehabilitation,†2014 1st International Symposium on Technology Management and Emerging Technologies (Istmet 2014), pp. 82–85, 2014.
[17] M. N. A. A. Patar et al., “Hand rehabilitation device system (HRDS) for therapeutic applications,†in 5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics, 2014, pp. 381–386.
[18] M. N. A. B. A. Patar, T. Komeda, J. Mahmud, and C. Y. Low, “Model Based Design of Finger Exoskeleton for Post Stroke Rehabilitation Using a Slotted Link Cam with Lead Screw Mechanism,†in Industrial Engineering, Management Science and Applications 2015, Berlin, Heidelberg: Springer Berlin Heidelberg, 2015, pp. 95–103.
[19] D. P. Ferris, K. E. Gordon, G. S. Sawicki, and A. Peethambaran, “An improved powered ankle-foot orthosis using proportional myoelectric control,†Gait and Posture, 2006.
[20] S. F. Tyson, E. Sadeghi-Demneh, and C. J. Nester, “A systematic review and meta-analysis of the effect of an ankle-foot orthosis on gait biomechanics after stroke,†Clinical Rehabilitation. 2013.
-
Downloads
-
How to Cite
Nor Azmi Ab Patar, M., Lee, H., Patar, A., Azmi Ayub, M., & Hamid, A. (2018). Low Cost Monitoring System of Ground Reaction Force during Normal Gait Cycle for Motion Control and Analysis of Active Ankle Foot Orthosis. International Journal of Engineering & Technology, 7(4.26), 318-321. https://doi.org/10.14419/ijet.v7i4.26.28568Received date: 2019-03-22